Dell Precision™ Workstations Fan Locations
Dell Precision Workstation 650 Computer
Dell Precision Workstation 450 Computer
Dell Precision Workstation 530 Computer
Dell Precision Workstation 620 Computer
NOTE: Part numbers listed with each fan are subject to change.
NOTE: Overtemp indicates that the processor temperature has risen, and it does not necessarly indicate a fan failure.
NOTE: Thermtrip indicates a catastrophic failure.
Dell Precision Workstation 650 Computer
Error Messages
Fan Failure
AGP cardcage fan
CPU 0 fan
CPU 1 fan
CPU 0
Overtemp
Boot Message (F1/F2)
Event Log Message
During
boot
Alert! Card-cage fan failure
Out of Range
Card-cage Fan
Run
time
On next boot: Alert! Previous fan failure
Out of Range
Card-cage Fan
During
boot
Alert! CPU 0 Fan Failure
Out of Range CPU
0 Fan
Run
time
On next boot: Alert! Previous fan failures
Out of Range CPU
0 Fan
During
boot
Alert! CPU 1 fan failure
Out of Range CPU
1 Fan
Run
time
On next boot: Alert! Previous Fan Failure
Out of Range CPU
1 Fan
During
boot
NOTE: The computer will shut down if this issue is not
resolved within about 1 minute.
On next boot: Alert! Previous processor thermal failure
Run
time
NOTE: The computer will shut down if this issue is not
resolved within about 1 minute.
On next boot: Alert! Previous processor thermal failure
CPU 1
Overtemp
During
boot
NOTE: The computer will shut down if this issue is not
resolved within about 1 minute.
On next boot: Alert! Previous processor thermal failure
Run
time
NOTE: The computer will shut down if this issue is not
resolved within about 1 minute.
On next boot: Alert! Previous processor thermal failure
System
Thermtrip
During
boot
System immediately shuts down!
Run
System immediately shuts down!
On next boot: Alert! Previous shutdown due to thermal event
Out of range CPU 0
Temperature
Out of range CPU 0
Temperature
Out of range CPU 1
Temperature
Out of range CPU 1
Temperature
time
Power supply During
fan 1
boot
Run
time
Power supply During
fan 2
boot
Run
time
On next boot: Alert! Previous shutdown due to thermal event
Alert! Power supply fan failure
Out of Range
Power Supply Fan 1
Alert! Previous fan failure
Out of Range
Power Supply Fan 1
Alert! Power supply fan failure
Out of Range
Power Supply Fan 2
Alert! Previous fan failure
Out of Range
Power Supply Fan 2
PN 0U231 — CPU fan, independently replaceable, two per system
1
CPU 1 fan
2
CPU 0 fan
PN 5M486 — AGP card cage fan
PN 1M475 — Power supply fan, 460W (dual fan power supply)
1
power supply fans (2)
Dell Precision Workstation 450 Computer
Error Messages
Fan Failure
CPU 0 fan
CPU 1 fan
CPU 0
Overtemp
Boot Message (F1/F2)
Event Log Message
During
boot
Alert! CPU 0 Fan Failure
Out of Range CPU
0 Fan
Run
time
On next boot: Alert! Previous fan failures
Out of Range CPU
0 Fan
During
boot
Alert! CPU 1 fan failure
Out of Range CPU
1 Fan
Run
time
On next boot: Alert! Previous Fan Failure
Out of Range CPU
1 Fan
During
boot
NOTE: The computer will shut down if this issue is not
resolved within about 1 minute.
On next boot: Alert! Previous processor thermal failure
Run
time
NOTE: The computer will shut down if this issue is not
resolved within about 1 minute.
On next boot: Alert! Previous processor thermal failure
CPU 1
Overtemp
During
boot
NOTE: The computer will shut down if this issue is not
resolved within about 1 minute.
On next boot: Alert! Previous processor thermal failure
Run
time
NOTE: The computer will shut down if this issue is not
resolved within about 1 minute.
On next boot: Alert! Previous processor thermal failure
System
Thermtrip
During
boot
System immediately shuts down!
Run
time
System immediately shuts down!
Power supply During
fan 1
boot
Run
time
Power supply During
fan 2
boot
Run
time
Out of range CPU 0
Temperature
Out of range CPU 0
Temperature
Out of range CPU 1
Temperature
Out of range CPU 1
Temperature
On next boot: Alert! Previous shutdown due to thermal event
On next boot: Alert! Previous shutdown due to thermal event
Alert! Power supply fan failure
Out of Range
Power Supply Fan 1
Alert! Previous fan failure
Out of Range
Power Supply Fan 1
Alert! Power supply fan failure
Out of Range
Power Supply Fan 2
Alert! Previous fan failure
Out of Range
Power Supply Fan 2
PN 7P974 — Dual CPU fans/shroud assembly
1
CPU 0 fan
2
CPU 1 fan
PN 2P222 — Power supply fan, 360W
1
power supply fans (2)
Dell Precision Workstation 530 Computer
Fan Failure
Boot Message (F1/F2)
Event Log Message
AGP card-cage During
fan
boot
Alert! Card cage fan not detected
Out Of Range Card-cage
Fan
Run time On next boot: Alert! Previous fan failure
CPU 0 fan
CPU 1 fan
CPU 0
Overtemp
During
boot
Alert! CPU 0 fan not detected
Out Of Range Card-cage
Fan
Out Of Range CPU 0 Fan
Run time On next boot: Alert! Previous fan failure
Out Of Range CPU 0 Fan
During
boot
Alert! CPU 1 fan not detected
Out Of Range CPU 1 Fan
Run time On next boot: Alert! Previous fan failure
Out Of Range CPU 1 Fan
During
boot
NOTE: The computer will shut down if this issue is not resolved
within about 1 minute.
Out Of Range CPU 0
Temperature
On next boot: Alert! Shutdown due to thermal event
Run time NOTE: The computer will shut down if this issue is not resolved
within about 1 minute
Out Of Range CPU 0
Temperature
On next boot: Alert! Previous temperature failure at Processor 1
CPU 1
Overtemp
During
boot
NOTE: The computer will shut down if this issue is not resolved
within about 1 minute.
Out Of Range CPU 1
Temperature
On next boot: Alert! Previous shutdown due to thermal event
Run time NOTE: The computer will shut down if this issue is not resolved
within about 1 minute.
Out Of Range CPU 1
Temperature
On next boot: Alert! Previous temperature failure at Processor 2
Power supply
fan 1
Power supply
fan 2
System
Thermtrip
During
boot
Alert! Power supply fan failure
Out Of Range Power
Supply Fan 1
Run time On next boot: Alert! Previous fan failure
Out Of Range Power
Supply Fan 1
During
boot
Alert! Power supply fan failure
Out Of Range Power
Supply Fan 2
Run time On next boot: Alert! Previous fan failure
Out Of Range Power
Supply Fan 2
During
boot
Out Of Range CPU 0
Temperature
System immediately shuts down!
On next boot: Alert! Previous shutdown due to thermal event
Run time System immediately shuts down!
On next boot: Alert! Previous shutdown due to thermal event.
System
Thermtrip
During
boot
System immediately shuts down!
On next boot: Previous shutdown due to thermal event
Run time System immediately shuts down!
On next boot: Alert! Previous shutdown due to thermal event
PN 929FF — CPU fan, independently replaceable, two per system
Out Of Range CPU 0
Temperature
Out Of Range CPU 1
Temperature
Out Of Range CPU 1
Temperature
1
CPU 1 fan
2
CPU 0 fan
PN 0C252 — AGP card cage fan
PN 1M475 — Power supply fan, 460W
1
power supply fans (2)
Dell Precision Workstation 620 Computer
NOTE: Precision Workstation 620 computers do not have an event log.
Fan Failure
AGP card-cage fan
CPU fan
CPU 0
Overtemp
Boot Message (F1/F2)
During
boot
No message
Run time
No message
During
boot
Alert! CPU fan not detected
Run time
On next boot: Alert! Previous system fan failure
During
boot
NOTE: The computer will shut down if this issue is not resolved within about 1
minute.
On next boot: Alert! Previous shutdown due to thermal event
CPU 1
Overtemp
During
boot
NOTE: The computer will shut down if this issue is not resolved within about 1
minute
On next boot: Alert! Previous temperature failure at Processor 1
System
Thermtrip
During
boot
System immediately shuts down!
Run time
System immediately shuts down!
On next boot: Alert! Previous shutdown due to thermal event
On next boot: Alert! Previous shutdown due to thermal event
Power supply fan 1
Power supply fan 2
System fan (memory riser
fan)
During
boot
Alert! Power supply fan failure
Run time
On next boot: Alert! previous power supply fan failure
During
boot
Alert! Power supply fan failure
Run time
On next boot: Alert! Previous power supply fan failure
During
boot
Alert! System fan not detected
Run time
On next boot: Alert! Previous system fan failure
PN D0744 — CPU/system fan (service kit to replace fan, not the bracket, which can
be reused.)
PN 8329R — AGP fan
PN 7069P — Memory riser fan
1
memory riser fan
PN 41UFC — Power supply fans
1
power supply fans (2)
Information in this document is subject to change without notice.
© 2003 Dell Computer Corporation. All rights reserved. Printed in the U.S.A.
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden.
Trademarks used in this text: Dell, Dell Precision, and the DELL logo are trademarks of Dell Computer Corporation. Other trademarks and trade
names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Computer Corporation
disclaims any proprietary interest in trademarks and trade names other than its own.