ANL15102515 F Report
2016-04-05
: Pdf Anl15102515-F Report ANL15102515-F_report CertsReports 101899 ProductFiles
Open the PDF directly: View PDF .
Page Count: 14
Download | ![]() |
Open PDF In Browser | View PDF |
FCC TEST REPORT Report Number: ANL15102515-F Equipment under test(EUT): AC adapter Model No.: DK-090M Applicant: DAKAI ELECTRONIC TECHNOLOGY(HK) CO., LIMITED FLAT/RM B 8/F CHONG MING BLDG 72 CHEUNG SHA WAN ROAD KOWLOON HONG KONG Date of Test: October 29, 2015 Date of Issue: November 5, 2015 Test Standards FCC CFR47 Part15 Subpart B The device described above is tested by Ankel Testing (DongGuan) Co., Ltd. to determine the maximum emission levels emanating from the device, the severe levels which the device can endure and performance criterion. The sample detailed above has been tested to the requirements of Council Directives ANSI C63.4:2009. The test results have been reviewed against the Directives above and found to meet their essential requirements Without written approval of Ankel Testing (DongGuan) Co., Ltd., the test report shall not be reproduced except in full. Approved By: Tested By: Manager Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 1 of 14 1 1 2 3 4 5 6 7 Contents Contents ........................................................................................................................................................ 2 EUT(Equipment Under Test) Information ................................................................................................ 3 2.1 Client Information ................................................................................................................................. 3 2.2 Description of E.U.T. ............................................................................................................................. 3 2.3 Power Supply of E.U.T. ......................................................................................................................... 3 2.4 Description of Support Units ................................................................................................................. 3 2.5 Test Facility ........................................................................................................................................... 3 2.6 Test Uncertainty ..................................................................................................................................... 4 Test Results Summary ................................................................................................................................. 4 Test Instrument During Test ....................................................................................................................... 5 4.1 Radiated Emission ................................................................................................................................. 5 4.2 Conducted Emission&Disturbance Power ............................................................................................. 5 Conducted Disturbance at the Mains Ports............................................................................................... 6 5.1 Test Standard.......................................................................................................................................... 6 5.2 Limits for Conducted Disturbance ......................................................................................................... 6 5.3 Test Set-up ............................................................................................................................................. 6 5.4 Test Procedure ....................................................................................................................................... 7 5.5 Operating Condition of EUT ................................................................................................................. 7 5.6 Test Results and Data............................................................................................................................. 7 Radiated Emission Test ............................................................................................................................. 10 6.1 Test Standard........................................................................................................................................ 10 6.2 Limits of Radiated Emission(3m) ........................................................................................................ 10 6.3 Test Set-up ........................................................................................................................................... 10 6.4 Test Procedure ......................................................................................................................................11 6.5 Operating Condition of EUT ................................................................................................................11 6.6 Test Results and Data............................................................................................................................11 Photographs - Constructional Details ...................................................................................................... 13 7.1 EUT - Front View ................................................................................................................................ 13 7.2 EUT - Back View ................................................................................................................................. 13 7.3 PCB - Front View ................................................................................................................................ 14 7.4 PCB - Back View ................................................................................................................................. 14 Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 2 of 14 2 EUT(Equipment Under Test) Information 2.1 Client Information Applicant : DAKAI ELECTRONIC TECHNOLOGY(HK) CO., LIMITED Address of Applicant: FLAT/RM B 8/F CHONG MING BLDG 72 CHEUNG SHA WAN ROAD KOWLOON HONG KONG Manufacturer: Address of Manufacturer: DAKAI ELECTRONIC TECHNOLOGY(HK) CO., LIMITED Liheng Industrial Park, QingXi Town, DongGuan City, GuangDong Province, China 2.2 Description of E.U.T. Product Name: AC adapter Model No.: DK-090M 2.3 Power Supply of E.U.T. Input: 220-240V~, 50/60Hz 2.4 Description of Support Units The EUT has been tested as an independent unit. 2.5 Test Facility The test facility is recognized, certified, or accredited by the following organizations: Name of Facility : Solid Industrial (Shenzhen) Co., Ltd. EMC Laboratory Location Site Description : Solid Industrial (Shenzhen) Co., Ltd. at 333 Bulong Highway Buji Longgang, Shenzhen, Guangdong, China. :April 06. 2004 accredited by Voluntary Control Council for Interference by information Technology Equipment for Laboratories Registration Number:2153 Solid Industrial (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration 759397, December 28, 2006. Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 3 of 14 2.6 Test Uncertainty Conducted Emission Uncertainty : ± 2.66dB Radiated Emission Uncertainty : ± 3.56dB 3 Test Results Summary Test Items Test Requirement Test Method Results Conducted Emission FCC Part 15, Subpart B ANSI C63.4: 2009 PASS FCC Part 15, Subpart B ANSI C63.4: 2009 PASS (150kHz to 30MHz) Radiated Emission (30MHz to 1GHz) Note: Above test marking “N/A” is not applicable. Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 4 of 14 4 Test Instrument During Test 4.1 Radiated Emission Equipment Brand Name Model Cal. Int Months Last Cal. Date EMC Analyzer Agilent E7402A 12 2015-08 EMI Test Receiver R&S ESS 12 2015-08 Pre Amplifier Anritsu MH648A 12 2015-08 Bilog Antenna SCHAFFNER CBL6111C 12 2015-08 Panasonic VP-8122A 12 Signal Generator R&S SMG 12 2015-08 RF Selector TOYO NS4901A - - Turn Disc HD DS4150S - - Antenna Mast HD MA2400 - - AM/FM Stereo Signal Generator 2015-08 4.2 Conducted Emission&Disturbance Power Equipment Brand Name Model Cal. Int Months Last Cal. Date Spectrum analyzer ADVANTEST R3261C 12 2015-08 EMI Test Receiver R&S ESS 12 2015-08 Pre Amplifier Anritsu MH648A 12 2015-08 LISN Kyoritsu KNW-403D 12 2015-08 LISN Kyoritsu KNW-407 12 2015-08 LISN Kyoritsu KNW-242C 12 2015-08 Absorbing Clamp R&S MDS-21 12 2015-08 Absorbing Clamp R&S MDS-21 12 2015-08 KT-20 12 - MAK-6578A 12 2015-08 VP-8122A 12 2015-08 Absorbing Clamp Distortion Meter Kyoritsu MEGURO AM/FM Stereo Signal Panasonic Generator Oscilloscope LEADER LS1020 12 2015-08 Function Generator National VP-7422A 12 2015-08 Signal Generator R&S SMG 12 2015-08 RF Selector TOYO NS4000 - - RF Selector TOYO NS4900 - - Remote Controller TOYO MAC - - Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 5 of 14 5 Conducted Disturbance at the Mains Ports 5.1 Test Standard FCC CFR47 Part15 Subpart B 5.2 Limits for Conducted Disturbance Frequency range MHz 0.15 to 0.50 0.50 to 5 5 to 30 Limits dB(μV) Quasi-peak 66 to 56 56 60 Average 56 to 46 46 50 NOTE 1 At the transition frequency, the lower limit applies. NOTE 2 The limit decreasing linearly with the logarithm of the frequency in range 0.15MHz to 0.50MHz. 5.3 Test Set-up Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 6 of 14 5.4 Test Procedure a. The EUT was placed on a desk 0.8 meter height from the metal ground plane and 0.4 meter from the conducting wall of the shielding room and it was kept at least 0.8 meter from any other grounded conducting surface. b. Connect EUT to the power mains through a line impedance stabilization network(LISN). c. All the support units are connect to the other LISN. d. The LISN provides 50 ohm coupling impedance for the measuring instrument. e. The CISPR states that a 50ohm, 50 microhenry LISN should be used. f. Both sides of AC line were checked for maximum conducted interference. g. The frequency range from 150kHz to 30MHz was searched. h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maxium Hold Mode. 5.5 Operating Condition of EUT Operating Environment: Temperature: 24.0°C Humidity: 52 % RH Barometric Pressure: 1012 mbar EUT Operation: Compliance test was performed in ON mode connected with the full load. 1:Setup the EUT and simulators as shown in Section 5.3. 2:Turn on the power of all equipments. 3:Let the EUT work in test modes and test it. 5.6 Test Results and Data Test Date: October 29, 2015 PASS. The frequency spectrum from 150 kHz to 30 MHz is investigated. Corrected Reading(dBμV) = Insertion Loss + Cable Loss + Read Level = Level Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 7 of 14 L Line: Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 8 of 14 N Line: Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 9 of 14 6 Radiated Emission Test 6.1 Test Standard FCC Part 15.109 Class B 6.2 Limits of Radiated Emission(3m) Frequency MHz 30~88 88~216 216~960 960~1000 Limits dB(μV/m) QP Level 40 43.5 46 54 6.3 Test Set-up Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 10 of 14 6.4 Test Procedure a. The EUT was placed on a rotatable table top 0.8 meter above ground. b. The EUT was set 3 meters from the interference-receiving antenna which was mounted on the top of a variable height antenna tower. c. The table was rotated 360 degrees to determine the position the highest radiation. d. The antenna height is varied between one meter and four meters above ground to find the maximum value of the field strength both horizontal polarization and vertical polarization of the antenna are set to make the measurement. e. For each suspected emission the EUT was arranged to its worst case and then tune the antenna tower(from 1M to 4M) and turn table (from 0 degress to 360 degrees) to find the maximum reading. f. Set the test-receiver system to peak Detect Function and specified bandwidth with Maximum Hold Mode. g. If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, then testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3dB margin will be repeated one by one using the quasi-peak method and reported. 6.5 Operating Condition of EUT Operating Environment: Temperature: 24.0°C Humidity: 52 % RH Barometric Pressure: 1012 mbar EUT Operation: Compliance test was performed in charging and lighting mode. 1:Setup the EUT and simulators as shown in Section 6.3. 2:Turn on the power of all equipments. 3:Let the EUT work in test modes and test it. 6.6 Test Results and Data Test Date: October 29, 2015 PASS. The frequency range 30MHz to1000MHz is investigated. Corrected Reading: Antenna Factor + Cable Loss + Read Level – Preamp Factor = Level EUT: AC adapter Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 11 of 14 Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 12 of 14 7 Photographs - Constructional Details 7.1 EUT - Front View 7.2 EUT - Back View Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China Report No.: ANL15102515-F Page 13 of 14 7.3 PCB - Front View 7.4 PCB - Back View --------------------------- END Ankel Testing (DongGuan) Co., Ltd KaiGao South Plaza, XinXiBian GuanChang Road, DongCheng District, DongGuan, GuangDong, China -------------------------Report No.: ANL15102515-F Page 14 of 14
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2015:11:06 18:34:17+08:00 Create Date : 2015:11:06 18:33:57+08:00 Metadata Date : 2015:11:06 18:34:17+08:00 Format : application/pdf Title : Microsoft Word - ANL15102515-F report Creator : Administrator Document ID : uuid:35f9b197-f3b0-4965-8617-6a0a9b42c288 Instance ID : uuid:447e6c32-1653-4adb-b0bc-28aebff2cb5e Page Count : 14 Author : AdministratorEXIF Metadata provided by EXIF.tools